Zerio radio system
Small, simple and low cost, the Zerio is designed for use in smaller installations and adaptable to buildings where other radio fire alarm systems may be unsuitable.
Once installed, the control panel aids system set-up, device programming and commissioning. The service, addition or removal of devices does not require special programming equipment, only a standard PC keyboard at most.
If devices are needed beyond the range of the control panel a radio sounder can be configured as a booster unit with the addition of a power supply unit. Up to 5 of these boosters (running off mains power) can serve one panel.
 |
Key Features

· Fully addressable, 99 devices maximum over 8 zones
· Compact design
· Easy to install, programme, use and service
· No expensive ancillary programming equipment required
· High visibility LCD display with backlight
· 48hr standby as standard
· Programmable fire and fault relay
· Two latching or non latching inputs
· Self Radio surveying
· Fully compliant to EN54-2 and BS5839 Part 4
|
Specifications
| Maxi number of zones | 8 |
| Maxi number of devices | 99 |
| Maxi number of booster units | 5 |
| Panel dimensions | 290 x 220 x 85mm |
| Weight (excluding battery) | 4kg |
| Alarm indicators | Twin red Common Fire 8x red zone indication Status & location text on display, up to 60 characters |
| Fault indicators | 5x yellow indicators Status/device detail on display |
| Status indicators | 4 yellow & 1 green supply indicator |
| LCD screen | 4-line display with yellow-green backlight |
| Programmed using | · Panel controls, plus · PC interface (with adapter, not supplied), or · Standard PS/2 PC keyboard |
| Access levels | Code protected - level 1: basic user, level 2: advanced user, level 3: service engineer, level 4: commissioning engineer |
| Mains supply | 220-240V 50Hz 0.2A max. |
| Standby battery | 12v 3Ah maxi. |
| Auxiliary relays | 1x Fire, 1x Fault |
| Relay configuration | Single pole changeover, 30v 1A maxi. |
| Inputs | 2x open/short circuit monitored for hardwired MCPs or interlinks, programmable for latching or non latching action, 4K7 end of line and 470 ohm alarm resistors required for operation |
| Operating frequency | 173.225MHz |
| Modulation | NBFM |
| Output power (ERP) | 10mW |
| Operating temperature range | 0 to +60°C |
| Applicable standards | EN54 – 2, BS5839 Part 4, EN300 220, EN301 489-3 & EN50130-4 |
Order Codes
| EDA-Z1000 | Zerio radio fire alarm control panel |
| EDA-U100 | Zerio radio sounder unit |
| EDA-U010 | PSU for U100 to convert to booster unit |
| EDA-X100 | Zerio radio call point |
| EDA-W100 | Zerio radio optical smoke detector |
| EDA-W200 | Zerio combined optical smoke detector with sounder |
| EDA-V100 | Zerio radio heat detector |
| EDA-V200 | Zerio combined heat detector with sounder |
Radio strobe beacons, relays and other devices also available, please contact us for details. Note that Millennium series radio devices will not work with the Zerio system.
|
|











 |